RW Manual-1
RANEWARE OPERATORS MANUAL ECS
ENGINEERED CONFERENCE SYSTEMS
Contents
INSTALLING RANEWARE........................................ 2
ABOUT ECS RANEWARE ........................................ 4
APPLICATIONS & USING PRESETS ..................13
SITE SURVEY & SYSTEM CHECKLIST..............20
ECS ALIGNMENT PROCEDURE ..........................21
TROUBLESHOOTING..............................................23
ECB 62E DEVICE CONTROL LANGUAGE .........24
ECS RaneWare Manual
This manual contains information on RaneWare soft-
ware installation and ECS controls, device control language,
system setup, applications and operation.
All software controls are printed here in sans-serif type
to help distinguish between hardware and software.
ECS consists of software-driven hardware. Consult the
ECS Hardware Manual for the ECB 62e Base and ECM
82e Mixer installation options, audio and data connections,
control and indicator descriptions, and audio specifications.
This manual first begins with RaneWare installation,
then describes all software controls, and those particular to
ECS. Applications & Using Presets describes example
systems that may be used as a starting point for your own
customized application. A Checkist and Site Survey
addresses questions that may arise during installation or
operation. After the system is connected and installed in
place, the Alignment Procedure may begin. For those using
control systems such as AMX or Crestron, the Device
Control Language is provided.
Overview
ECS is hardware controlled by software. RaneWare®
is the software, and the family of products that the
software controls. RW 232™ describes the protocol and
the DB-9 hardware used to communicate between units.
The ECB 62e Base is controlled through the RW 232
serial bus. This interface operates on any RS-232 serial
port, allowing control system communication with up to
16 RW 232 products at a time, each with a unique
address. The ECM 82e Mixers are controlled through the
Base using a proprietary Expansion Interface cable. Rane
RW 232 products can be controlled from remote locations
with the optional RPD 1 Programming & Diagnostics
Unit or the Via 10 Ethernet Bridge (see the respective
data sheets).
ECS is covered by US Patent 5,848,146
RaneWare is a registered trademark of Rane Corporation
Windows is a registered trademark of Microsoft Corporation
Note: RaneWare is a 16-bit program written to run on
Windows 95, 98SE and earlier OS's like Windows 3.1,
though in some instances will not work on Windows NT, and
most instances 2000, ME and XP are inconsistent. The
crashing is caused by the WOW32.DLL in later OS versions
not being compatible with RaneWare and other file issues.
Officially we support only the Windows 98SE and earlier
operating systems. The only solution is to run the earlier
version: Windows 95 or 98SE. Other OS's might work but we
can't guarantee or support all the variables.
Windows NT 4.0 seems fine, but you cannot print
consistently with version 2.3. RaneWare version 2.2 does
seem to print correctly under NT 4.0.
RaneWare does not work in any modes under Windows
2000. It "crashes and burns" if not immediately after startup,
then soon after. WOW32.DLL is the most common problem
witnessed under Windows 2000.
Under Windows ME, it seems "OK" in offline mode and
fairly inconsistent in online (i.e. hardware connected) mode.
Under Windows XP, offline mode seems "OK" but online
mode is anybody's guess. It varies wildly depending on if it's
a desktop versus laptop machine and also what type of ports
are on the unit. Machines sporting USB ports running XP are
far more likely to experience issues when polling for our
hardware.
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - RANEWARE OPERATORS MANUAL ECS

RW Manual-1RANEWARE OPERATORS MANUAL ECSENGINEERED CONFERENCE SYSTEMSContentsINSTALLING RANEWARE... 2ABOUT ECS RA

Seite 2 - INSTALLING RANEWARE

RW Manual-10System tabProg Sig ThreshProgram Signal Threshold adjusts the point at whichaudio is detected at the Port 1 Output, thus causing theProgra

Seite 3 - Device Selection

RW Manual-11Near Signal Offset signal flowQuery the ECB 62e for the Master Port OPSTAT param-eter to decide which video feed to switch to. (A preposit

Seite 4 - ECS RANEWARE

RW Manual-12Prog Sig ReleaseOne can think of this parameter as either the longestdistance or delay time between a speaker and a Mic in theroom, or thi

Seite 5 - RW Manual-5

RW Manual-13In this application, Port Inputs must be Selected by theRoom Controller. The laptop is only used for the initialsystem setup. It is then r

Seite 6 - RW Manual-6

RW Manual-14 This block diagram illustrates the Applications - System 1 example on the preceding page.

Seite 7 - RW Manual-7

RW Manual-15This unit-to-unit wiring diagram illustrates the Applications - System 1 example on the preceding pages.

Seite 8 - RW Manual-8

RW Manual-16RaneWare Folders forAPI.ECS Memory 2

Seite 9 - RW Manual-9

RW Manual-17System 2: Boardroom with Program StereoThe following illustrates an ECS with 16 mics, stereo program speakers, mono ceilingspeakers, a dig

Seite 10 - System tab

RW Manual-18System 3: Distance LearningThis illustrates a distance learning application usingbroadband video that requires reinforcement of the teache

Seite 11 - RW Manual-11

RW Manual-19System 4: Large Conference CenterThe following illustrates a large ECS with 40 Mics (16ceiling and 24 table), stereo program and a six zon

Seite 12 - RW Manual-12

RW Manual-2Starting RaneWareOnce RaneWare is installed, a RaneWare program groupis created. When the software is first installed, Rane’sSoftware Licen

Seite 13 - Conference Room

RW Manual-20SITE SURVEYFor ECS to operate properly the following must be closelyobserved:Ambient Noise Level - Air conditioning equipment (listenfor r

Seite 14 - RW Manual-14

RW Manual-21QUICK OVERVIEWa. Set up the ECM 82e Mic levels.b. Set up the Input levels to the ECB 62e.c. Set the Mic operation for each Input on the EC

Seite 15 - RW Manual-15

RW Manual-22TROUBLESHOOTINGNo communication between the unit and computer:Set the DEVICE ADDRESS to a unique small number,and try polling for units in

Seite 16 - RW Manual-16

RW Manual-23Definition: Two’s Complement: The result ob-tained when all the data bits are invertedand 1 is added to the result. Used torepresent negat

Seite 17 - RW Manual-17

RW Manual-24CS = $59MyData = "$00, $07, $81, $00, $00, $00, $19, $06, $59"Add extra $FB (None detected)Send MyDataNote: AMX has special ESC

Seite 18 - System 3: Distance Learning

RW Manual-25Index Hex Mixer 1 Parameters:67-70 $43-46 (reserved) 0 (byte)71 $47 NOMM Mode (On/Off)* 1/0 (byte) 1 = On, 0 = Off72 $48 Output (On/Off)*

Seite 19 - RW Manual-19

RW Manual-26393-399 Mic 40 Parameters Same as Mic 1 Parameters400-406 Mic 41 Parameters Same as Mic 1 Parameters407-413 Mic 42 Parameters Same as Mic

Seite 20 - SYSTEM CHECKLIST

RW Manual-27Memory number codes (MEMNUM):$00 = live or working memory, $01 = preset memory #1, $02 = preset memory #2, ... , $10 = preset memory #16 (

Seite 21 - ECS ALIGNMENT PROCEDURE

RW Manual-28Lock device (85 hex):Transmit ADDR header ($FB xx FB xx, where xx = ADDR)Get DTGet IDTransmit $00 $02 (where $00 02 = number of data bytes

Seite 22 - TROUBLESHOOTING

RW Manual-29SNPL Stored Name Parameter List (SNPL):Index Hex Parameters Encoding Method00-08 $00-$08 Output Name 1 8 (char)09-16 $09-$10 Outpu

Seite 23 - Control Systems

RW Manual-3Memory & SecurityECS can be operated on a daily basis through a computerif a system controller is not installed. To preserve memorysecu

Seite 24 - RW Manual-24

RW Manual-30Get data from channel (01 hex):Transmit ADDR header ($FB xx FB xx, where xx = ADDR)Get DTGet IDTransmit $00 $08 (where $00 08 = number of

Seite 25 - RW Manual-25

RW Manual-31Get Expansion Revisions (0A hex):Transmit ADDR header ($FB xx FB xx, where xx = ADDR)Get DTGet IDTransmit $00 $02 (where $00 02 = number o

Seite 26 - ECB 62e Global Parameters

RW Manual-32RW 232 Communications InterfaceRW 232 is loosely based on PA-422. One key hardware difference is that RW 232 does not utilize hardware han

Seite 27 - RW 232 Commands

RW Manual-4ECS RANEWAREThere are 4 sections to the ECS controlling software:Status (top screen section)Port (1st tab)Mixer (2nd tab)System (3rd tab)Wh

Seite 28 - RW Manual-28

RW Manual-5Port PagePortThe Port tab allows configuration of the six individualECB 62e Ports. Status signals of a Port have no affect on Portaudio—thi

Seite 29 - RW Manual-29

RW Manual-6Off: Audio on this Port will not trigger the Port Signalindicator on, nor will the Port be able to become the Master.See also: Status Indic

Seite 30 - RW Manual-30

RW Manual-7MixerMixerThis selects one of six ECM 82e Mixers.Output buttonThis toggles the ECM 82e’s Mix Out between on (greenindicator, depressed butt

Seite 31 - RW Manual-31

RW Manual-8Mixer Max Mics OnSince conferencing applications are rarely intelligible withmultiple simultaneous talkers, Max Mics On sets the maxi-mum n

Seite 32 - RW Manual-32

RW Manual-9Mic Threshold LevelEach Mic has an independently adjustable ThresholdLevel. When audio is detected above this Threshold Level,the Mic Gates

Kommentare zu diesen Handbüchern

Keine Kommentare