Manual-1OPERATORS MANUAL RPM 26iDSP MULTIPROCESSORWindows is a registered trademark of Microsoft Corporation; RaneWare is a registered trademark of R
Manual-10Device > Name DeviceName Device allows you to name each RPM 26i and theirchannels. The device and channel names are stored in theunit. Typ
Manual-11The RaneWare Button Bar RPM 26i BasicsThe RPM 26i has 2 inputs, named Input A and Input B;and 6 outputs, named Output 1 through Output 6. To
Manual-12Choosing DSP ProgramsThe RPM 26i contains predefined DSP Programs. TheDSP Programs are “fixed” and the placement and order of thesignal proce
Manual-13Programming the RPM 26iThe RPM 26i and RPM 26v use the same software.References in software to the RPM 26v apply to theRPM 26i.Each DSP Progr
Manual-14OUTPUT TRIMThe Output Trim’s purpose is to provideup to 30 dB of attenuation on each Output.This is useful to adjust for speaker sensitivityi
Manual-15PARAMETRIC EQ (PEQ)Every DSP Program contains multi-bandparametric EQ, abbreviated PEQ. The quantity ofPEQ filters varies from program to pro
Manual-16EXTENDED PARAMETRIC (PEQ+)Some DSP Programs provide “Extended”Parametric EQ, abbreviated PEQ+. Extendedparametric simply means that two of th
Manual-17volume down for a given increase above the Threshold. TheAttack time dictates how quickly the signal reaches a“settled” compression level for
Manual-18FINE DELAYThe Fine Delay block has 20 microsecond(0.02 msec) minimum delay steps and isintended to allow individual driver alignmentin speake
Manual-19Once in Advanced mode, more edit boxes appear allowingprecise control of each individual filter type, slope andfrequency. This allows Linkwit
Manual-2FRONT PANEL DESCRIPTION햲 AES 3 LOCK & INPUT Signal/Overload multi-color LEDs indicate the presence of an AES3 clock, significant audioSign
Manual-20THE OVERALL RESPONSE CURVEDouble-clicking on any output’s screw terminal(shown at the right) opens the Overall Response curvewindow (shown be
Manual-21In addition to the individual signal processing blocksdescribed above, the RPM 26i contains Input Blocks andOutput Blocks, shown above. These
Manual-22TROUBLESHOOTINGPOWER LED is Off:Check the POWER connection on the chassis, and confirm that the remote supply is connected to a live AC sourc
Manual-23MEMORY RECALL PORTThe MEMORY RECALL PORT (MRP) provides contact closurecontrol to recall any of the 16 system Memories. Eight of the Memories
Manual-24©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.comSETTING THE DEVI
Manual-3REAR PANEL DESCRIPTION햲 Chassis Ground Point: This #6-32 screw and star washer provide chassis ground when needed. The RPM 26i chassisconnects
Manual-4SOFTWARE OPERATIONSTARTING RANEWAREIf RaneWare has not yet been installed on your computer,refer to STEP BY STEP RANEWARE INSTALLATIONabove. O
Manual-5Panel is all an operator needs to see to recall Memories. Ifonly a few presets are required, deleting the name entry in theSite Control Panel
Manual-6This window allows you to change the password. Thedefault password set by the factory at the time the softwareships is please. Passwords are c
Manual-7RaneWare’s Site Control Panel (shown at right) is a soundsystem re-configuration screen. It works by telling allconnected Rane RW 232 devices
Manual-8Device menuThis menu applies only to the single, selected device youare editing and contains the following:Device > SelectDevice > Choo
Manual-9This dialog allows you to configure the MRP (MemoryRecall Port) on newer versions of the RPM 26i beginningwith firmware rev 2.2.Each possible