Rane RPM 26i Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Audio Rane RPM 26i herunter. Rane RPM 26i User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Manual-1
OPERATORS MANUAL RPM 26i
DSP MULTIPROCESSOR
Windows
is a registered trademark of Microsoft Corporation; RaneWare is a registered trademark of Rane Corporation.
SYSTEM REQUIREMENTS
RaneWare works under Microsoft Windows
®
, on a PC or
laptop with an unused serial port.
RW 232, RaneWare’s protocol, uses a DB-9 cable less
than 50 feet long, connecting from the serial port of a com-
puter to the RPM 26i communications Input port. No inter-
face boxes are required; just a cable and your computer.
RaneWare can be fully demonstrated and used without an
actual RPM 26i attached. Simply select the OFFLINE
RPM 26i or any other OFFLINE unit under Select in the
Device menu.
A RaneWare CD-ROM comes with each unit. Installation
is simple. The latest version is downloadable 24 hours a day
from Rane’s Internet site: http://www.rane.com.
QUICK START
If you don’t read all of this document, you risk setting up your system improperly... but at least read this section and
the Input and Output Trim sections on pages Manual-13-14. Paying careful attention to your system’s gain structure is
essential to maximize the noise performance of your entire system. Once you’re done reading and memorizing the manual,
please recycle the paper it is printed on by reconing an old speaker. If RaneWare has not yet been installed on your
computer, refer to RANEWARE INSTALLATION on page Manual-4 first.
Leave the audio connections on the RPM 26i until last. Connect the RW 232 INPUT jack on the unit’s rear to a serial
(COM) port on a PC-compatible computer using a standard 9-pin RS-232 cable. A short one is supplied with the unit,
which is intended to connect between units in a rack. The cable and adapter must not be a null-modem type.
Locate the RW 232 DEVICE ADDRESS switch on the rear panel. If this unit is to be used by itself, set the switch to
1’ by setting all switches off (down), except switch one (labeled ‘1’ on the chassis, the right-most switch when viewed
from the rear). If there is more than one unit, refer to Device Address Calculator in the software’s Help system or run
the included Device Address Calculator software and set a unique address for each unit.
Apply power by connecting the RS 3 remote supply’s 5-pin DIN jack to the rear of the unit, then connect the IEC end
to a powered AC outlet. CAUTION: Do not connect anything but an approved Rane power supply to this jack. The unit
does ground the chassis through the power cord. If the RS 3 and the RPM 26i are getting power, the yellow front panel
POWER indicator will be on.
Start your computer, run Windows
®
, and launch RaneWare by double-clicking on the RaneWare™ umbrella icon.
(See the next page for software installation instructions.) The Help file’s Software License Agreement appears the first
time RaneWare is run — read it all and close it. Then the System Setup window may appear. If it doesn’t, select
System Setup from the System menu. Be careful to select the COM port which is physically connected to the RPM 26i.
Click OK. Now, the Device Selection window may appear. If it doesn’t, choose Select from the Device menu. Click on
Poll and the Devices Found: displays the units found. Click the Stop button to stop Polling. Select the unit from the
Device Selection window and click OK. If no unit was found, please refer to the TROUBLESHOOTING section at the
end of this manual or in the software’s Help system.
Several clues indicate communication between the computer and the RPM 26i. The yellow COM (communications)
indicator on the front of the unit flashes or stays on. The Memory numbers (1-16) near the top of the computer screen will
be black rather than gray. The Active indicator at the bottom left of the computer screen will be green.
Important Note: The RPM 26i contains many insightful, preprogrammed DSP Programs. Each “fixed” DSP Program
can be thought of as a unique “system setup,” i.e., 2-way crossover system, 3-way system, 2 x 6 splitter, etc. Each of the 16
Memories can contain a different DSP Program. Before connecting the RPM 26i to the other audio components in your
system, it is wise to choose and store the appropriate DSP Program for your system in all 16 Memories. This avoids the
problem of accidentally recalling a Memory that restores an undesired DSP Program, such as the case where you recall
from a 3-way DSP Program to a splitter: this sends full-range audio to all Outputs!
Once the proper DSP Program is stored in the RPM’s Memories, digital and audio connections can be made. Turn the
amplifier(s) off until all connections are complete.
Note: If you have previously
installed an older version of RaneWare
and you just received a new RPM 26i
unit, you must reinstall the new
version of RaneWare that was shipped
with your unit. Use of an old version
will not work.
WEAR PARTS: This product contains no wear parts.
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - OPERATORS MANUAL RPM 26i

Manual-1OPERATORS MANUAL RPM 26iDSP MULTIPROCESSORWindows is a registered trademark of Microsoft Corporation; RaneWare is a registered trademark of R

Seite 2 - RPM 26i CONNECTION

Manual-10Device > Name DeviceName Device allows you to name each RPM 26i and theirchannels. The device and channel names are stored in theunit. Typ

Seite 3 - REAR PANEL DESCRIPTION

Manual-11The RaneWare Button Bar RPM 26i BasicsThe RPM 26i has 2 inputs, named Input A and Input B;and 6 outputs, named Output 1 through Output 6. To

Seite 4 - RaneWare Installation

Manual-12Choosing DSP ProgramsThe RPM 26i contains predefined DSP Programs. TheDSP Programs are “fixed” and the placement and order of thesignal proce

Seite 5 - RaneWare Menus

Manual-13Programming the RPM 26iThe RPM 26i and RPM 26v use the same software.References in software to the RPM 26v apply to theRPM 26i.Each DSP Progr

Seite 6 - Manual-6

Manual-14OUTPUT TRIMThe Output Trim’s purpose is to provideup to 30 dB of attenuation on each Output.This is useful to adjust for speaker sensitivityi

Seite 7 - Manual-7

Manual-15PARAMETRIC EQ (PEQ)Every DSP Program contains multi-bandparametric EQ, abbreviated PEQ. The quantity ofPEQ filters varies from program to pro

Seite 8 - Manual-8

Manual-16EXTENDED PARAMETRIC (PEQ+)Some DSP Programs provide “Extended”Parametric EQ, abbreviated PEQ+. Extendedparametric simply means that two of th

Seite 9 - Manual-9

Manual-17volume down for a given increase above the Threshold. TheAttack time dictates how quickly the signal reaches a“settled” compression level for

Seite 10 - Manual-10

Manual-18FINE DELAYThe Fine Delay block has 20 microsecond(0.02 msec) minimum delay steps and isintended to allow individual driver alignmentin speake

Seite 11 - Manual-11

Manual-19Once in Advanced mode, more edit boxes appear allowingprecise control of each individual filter type, slope andfrequency. This allows Linkwit

Seite 12 - Manual-12

Manual-2FRONT PANEL DESCRIPTION햲 AES 3 LOCK & INPUT Signal/Overload multi-color LEDs indicate the presence of an AES3 clock, significant audioSign

Seite 13 - Programming the RPM 26i

Manual-20THE OVERALL RESPONSE CURVEDouble-clicking on any output’s screw terminal(shown at the right) opens the Overall Response curvewindow (shown be

Seite 14 - Manual-14

Manual-21In addition to the individual signal processing blocksdescribed above, the RPM 26i contains Input Blocks andOutput Blocks, shown above. These

Seite 15 - Manual-15

Manual-22TROUBLESHOOTINGPOWER LED is Off:Check the POWER connection on the chassis, and confirm that the remote supply is connected to a live AC sourc

Seite 16 - Manual-16

Manual-23MEMORY RECALL PORTThe MEMORY RECALL PORT (MRP) provides contact closurecontrol to recall any of the 16 system Memories. Eight of the Memories

Seite 17 - Manual-17

Manual-24©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.comSETTING THE DEVI

Seite 18 - Manual-18

Manual-3REAR PANEL DESCRIPTION햲 Chassis Ground Point: This #6-32 screw and star washer provide chassis ground when needed. The RPM 26i chassisconnects

Seite 19 - + markings indicates that I/O

Manual-4SOFTWARE OPERATIONSTARTING RANEWAREIf RaneWare has not yet been installed on your computer,refer to STEP BY STEP RANEWARE INSTALLATIONabove. O

Seite 20 - Manual-20

Manual-5Panel is all an operator needs to see to recall Memories. Ifonly a few presets are required, deleting the name entry in theSite Control Panel

Seite 21 - Manual-21

Manual-6This window allows you to change the password. Thedefault password set by the factory at the time the softwareships is please. Passwords are c

Seite 22 - TROUBLESHOOTING

Manual-7RaneWare’s Site Control Panel (shown at right) is a soundsystem re-configuration screen. It works by telling allconnected Rane RW 232 devices

Seite 23 - 87654321C

Manual-8Device menuThis menu applies only to the single, selected device youare editing and contains the following:Device > SelectDevice > Choo

Seite 24 - SETTING THE DEVICE ADDRESS

Manual-9This dialog allows you to configure the MRP (MemoryRecall Port) on newer versions of the RPM 26i beginningwith firmware rev 2.2.Each possible

Kommentare zu diesen Handbüchern